Cooling that fits your data center.

Choose your brand, cooling technology or heat load to reveal matching products. Inspect technical parameters, compare up to four options and request pricing on WhatsApp.

8 cooling brands 11 cooling categories Compare 4 solutions
Technical details? Contact Us ↗
Photograph of real server racks in a data center
Illustration of a generic unbranded precision cooling cabinet Generic precision cooling
DATA CENTER · COOLING SOLUTIONS

Explore cooling brands

01 / COOLING REQUIREMENT

Know your heat load?

Convert IT load to indicative cooling capacity in seconds, then explore matching solutions.

Try a load
Preliminary sizing only; final duty conditions, diversity and redundancy require engineering review.
IT load 40.0 kW
Indicative cooling 46.0 kW
Approximate tonnage 13.1 TR

Explore: In-row / rack-level / RDHx

Includes 15% allowance. These are preliminary system-level figures, not a guaranteed individual-unit capacity.

Explore cooling products

Browse the catalogue or narrow the list with filters and search.

57 matching cooling products Click to show or hide your selected products
Legrand
Availability on enquiry
Rear-door Heat Exchanger

ColdLogik CL20

CL20 Active RDHx
20–90 kW Capacity band
Chilled Water Cooling medium
High / AI-HPC Density fit
Rack rear-door Installation
Legrand
Availability on enquiry
Rear-door Heat Exchanger

ColdLogik CL21

CL21 Smart Passive
5–29 kW Capacity band
Chilled Water Cooling medium
Medium–high Density fit
Rack rear-door Installation
Legrand
Availability on enquiry
Rear-door Heat Exchanger

ColdLogik CL23

CL23 RDHx family
20–200 kW Capacity band
Chilled Water Cooling medium
Very high / AI-HPC Density fit
Rack rear-door Installation
Legrand
Availability on enquiry
In-row

ColdLogik InRow

ColdLogik InRow cooling
20–80 kW Capacity band
Chilled Water Cooling medium
Medium–high Density fit
Between racks Installation
APC
Availability on enquiry
Integrated / micro DC Ceiling

Uniflair Rack Mounted Room Cooling

Rack-mounted micro DC cooling
3–10 kW Capacity band
DX Cooling medium
Edge / micro DC Density fit
Rack integrated Installation
APC
Availability on enquiry
Room / CRAC

Uniflair Small Room Cooling

Small Room 5–20 kW family
5–20 kW Capacity band
DX Cooling medium
Low–medium Density fit
Perimeter / room Installation
APC
Availability on enquiry
Room / CRAC

Uniflair Med/Large Room Cooling

DX room cooling family
20–150 kW Capacity band
DX Cooling medium
Medium Density fit
Perimeter / room Installation
APC
Availability on enquiry
Room / CRAC

Uniflair Med/Large Room Cooling

Chilled-water room cooling family
20–250 kW Capacity band
Chilled Water Cooling medium
Medium–high Density fit
Perimeter / room Installation
APC
Availability on enquiry
In-row

Uniflair Direct Expansion InRow

DX InRow family
10–45 kW Capacity band
DX Cooling medium
Medium–high Density fit
Between racks Installation
APC
Availability on enquiry
In-row

Uniflair Chilled Water InRow

CW InRow family
20–70 kW Capacity band
Chilled Water Cooling medium
High Density fit
Between racks Installation
APC
Availability on enquiry
In-row

Easy Cooling Row CW

Easy Cooling Row CW
20–60 kW Capacity band
Chilled Water Cooling medium
Medium–high Density fit
Between racks Installation
APC
Availability on enquiry
Chiller

Uniflair Air Cooled Chillers

Mission-critical air-cooled chiller family
100–1600 kW Capacity band
Chilled Water Cooling medium
Facility scale Density fit
Outdoor plant Installation
APC
Availability on enquiry
Chiller

Uniflair Free Cooling Chillers

Integrated free-cooling chiller family
100–1600 kW Capacity band
Chilled Water Cooling medium
Facility scale Density fit
Outdoor plant Installation
APC
Availability on enquiry
Chiller

Uniflair Water Cooled Chillers

Water-cooled chiller family
200–2000 kW Capacity band
Chilled Water Cooling medium
Facility scale Density fit
Plant room Installation
APC
Availability on enquiry
Rear-door Heat Exchanger

Uniflair Rear Door Heat Exchanger

ChilledDoor® RDHx family
20–100 kW Capacity band
Chilled Water Cooling medium
High / AI Density fit
Rack rear-door Installation
APC
Availability on enquiry
Liquid / CDU

Uniflair Heat Dissipation Unit

Floor-mounted liquid-to-air HDU
50–200 kW Capacity band
Liquid Cooling medium
AI liquid cooling Density fit
Near racks / floor mounted Installation
APC
Availability on enquiry
Liquid / CDU

Uniflair Coolant Distribution

Liquid-to-liquid CDU family
100–1500 kW Capacity band
Liquid Cooling medium
AI / HPC Density fit
Row / facility Installation
APC
Availability on enquiry
Ceiling Suspended Cooling

Uniflair Ceiling Mounted Split Room Cooling

Ceiling-mounted split family
5–25 kW Capacity band
DX Cooling medium
Low–medium Density fit
Ceiling / room Installation
Vertiv
Availability on enquiry
PAC

Liebert DM

Small-room precision cooling family
7–30 kW Capacity band
DX Cooling medium
Low–medium Density fit
Floor / room Installation
Vertiv
Availability on enquiry
In-row

Liebert CRV

Row-based cooling unit
20–60 kW Capacity band
Hybrid Cooling medium
Medium–high Density fit
Between racks Installation
Vertiv
Availability on enquiry
In-row

Liebert CRV+

CRV+ row-based family
20–60 kW Capacity band
DX Cooling medium
Medium–high Density fit
Between racks Installation
Vertiv
Availability on enquiry
Integrated / micro DC Ceiling

Liebert DCL

Modular rack cooling
10–35 kW Capacity band
Chilled Water Cooling medium
Medium–high Density fit
Rack side attachment Installation
Vertiv
Availability on enquiry
Room / CRAC

Liebert PCW

35–170 kW chilled-water floor unit
35–170 kW Capacity band
Chilled Water Cooling medium
Medium–high Density fit
Floor / perimeter Installation
Vertiv
Availability on enquiry
Cool Wall

Liebert AHU

Modular data center AHU
100–300 kW Capacity band
Chilled Water Cooling medium
Large DC Density fit
Outside data hall Installation
Vertiv
Availability on enquiry
Cool Wall

Liebert CWA

200–500 kW chilled-water thermal wall
200–500 kW Capacity band
Chilled Water Cooling medium
High / hyperscale Density fit
Thermal wall Installation
Vertiv
Availability on enquiry
Chiller

Liebert AFC

CH3090 free-cooling chiller
300–900 kW Capacity band
Chilled Water Cooling medium
Facility scale Density fit
Outdoor plant Installation
Vertiv
Availability on enquiry
Chiller

Liebert AFC

CH3175 free-cooling chiller
900–1750 kW Capacity band
Chilled Water Cooling medium
Facility scale Density fit
Outdoor plant Installation
Vertiv
Availability on enquiry
Liquid / CDU

CoolChip CDU 70

Liquid-to-air CDU 70
50–70 kW Capacity band
Liquid Cooling medium
AI / high density Density fit
In-row / perimeter Installation
Vertiv
Availability on enquiry
Liquid / CDU

CoolChip CDU 121

In-rack 100kW+ CDU
100–120 kW Capacity band
Liquid Cooling medium
AI / high density Density fit
In-rack Installation
Climaveneta
Availability on enquiry
PAC

x-AV3-i-G02-DX-DF

029–108 full inverter dual-fluid
36.2–109 kW Capacity band
Hybrid Cooling medium
Medium–high Density fit
Perimeter / room Installation
Climaveneta
Availability on enquiry
Chiller

TR2-FC-G04-Z

840–1800 kW free-cooling chiller
840–1800 kW Capacity band
Chilled Water Cooling medium
Hyperscale plant Density fit
Outdoor plant Installation
Climaveneta
Availability on enquiry
Chiller

i-FX Chiller

Full inverter chiller range
100–1500 kW Capacity band
Chilled Water Cooling medium
Facility scale Density fit
Outdoor / plant Installation
Climaveneta
Availability on enquiry
Chiller

NX2

Air-cooled scroll chiller range
100–1000 kW Capacity band
Chilled Water Cooling medium
Facility scale Density fit
Outdoor plant Installation
STULZ
Availability on enquiry
In-row

CyberRow I-Series

11–58 kW row cooling
11–58 kW Capacity band
Chilled Water Cooling medium
High Density fit
Between racks Installation
STULZ
Availability on enquiry
Room / CRAC

CyberAir

Precision room cooling family
20–200 kW Capacity band
Hybrid Cooling medium
Medium–high Density fit
Perimeter / room Installation
STULZ
Availability on enquiry
Liquid / CDU

CyberCool CDU

Coolant Distribution Unit
100–1400 kW Capacity band
Liquid Cooling medium
AI / HPC Density fit
Row / facility Installation
STULZ
Availability on enquiry
Liquid / CDU

CyberCool Indoor

Indoor free-cooling chiller / CDU
100–1000 kW Capacity band
Liquid Cooling medium
AI / HPC Density fit
Indoor plant Installation
STULZ
Availability on enquiry
Integrated / micro DC Ceiling

Micro DC

Integrated micro data center
5–100 kW Capacity band
Hybrid Cooling medium
Edge–high density Density fit
Integrated rack Installation
STULZ
Availability on enquiry
Chip Level Cooling

Direct Chip Liquid Cooling

DCLC infrastructure
50–1500 kW Capacity band
Liquid Cooling medium
AI / HPC Density fit
Chip / rack / CDU Installation
Daikin
Availability on enquiry
Chiller

AWM

Air-cooled magnetic bearing chiller
500–2000 kW Capacity band
Chilled Water Cooling medium
Facility scale Density fit
Outdoor plant Installation
Daikin
Availability on enquiry
Chiller

AWV Pathfinder

Air-cooled screw chiller
300–1800 kW Capacity band
Chilled Water Cooling medium
Facility scale Density fit
Outdoor plant Installation
Daikin
Availability on enquiry
Chiller

WME Magnitude

Magnetic bearing centrifugal chiller
500–3000 kW Capacity band
Chilled Water Cooling medium
Hyperscale plant Density fit
Plant room Installation
Daikin
Availability on enquiry
Chip Level Cooling

DDC S-Series

Rack containment / precision GPU cooling platform
50–250 kW Capacity band
Hybrid Cooling medium
AI / GPU Density fit
Rack / containment Installation
FläktGroup
Availability on enquiry
Room / CRAC

Hydro-DENCO

High-capacity CRAH
100–500 kW Capacity band
Chilled Water Cooling medium
Large / hyperscale Density fit
Room / perimeter Installation
FläktGroup
Availability on enquiry
Cool Wall

Aria-DENCO

Fan Wall Unit
200–800 kW Capacity band
Chilled Water Cooling medium
Hyperscale Density fit
Fan wall Installation
FläktGroup
Availability on enquiry
PAC

Multi-DENCO

Close control cooling
20–120 kW Capacity band
Hybrid Cooling medium
Low–medium Density fit
Room / perimeter Installation
FläktGroup
Availability on enquiry
Room / CRAC

Ultra-DENCO

Downflow chilled-water unit
80–300 kW Capacity band
Chilled Water Cooling medium
Medium–high Density fit
Raised floor Installation
FläktGroup
Availability on enquiry
Chiller

FGFC 2123–3180 BF2

840–1800 kW free-cooling chiller
840–1800 kW Capacity band
Chilled Water Cooling medium
Hyperscale plant Density fit
Outdoor plant Installation
FläktGroup
Availability on enquiry
Liquid / CDU

Liquid-DENCO CDU

Coolant Distribution Unit
100–1500 kW Capacity band
Liquid Cooling medium
AI / HPC Density fit
Row / facility Installation
FläktGroup
Availability on enquiry
Cool Wall

CAIRplus

Air Handling Unit
100–700 kW Capacity band
Chilled Water Cooling medium
Large DC Density fit
AHU / wall Installation
Rittal
Availability on enquiry
In-row

LCP Inline DX

SK 3311430
10–35 kW Capacity band
DX Cooling medium
Medium Density fit
Bayed / inline Installation
Rittal
Availability on enquiry
In-row

LCP Inline DX

SK 3313430
10–35 kW Capacity band
DX Cooling medium
Medium Density fit
Bayed / inline Installation
Rittal
Availability on enquiry
In-row

LCP Inline DX

SK 3313470
10–35 kW Capacity band
DX Cooling medium
Medium Density fit
Bayed / inline Installation
Rittal
Availability on enquiry
Integrated / micro DC Ceiling

LCP Rack CW

SK 3312250
20–55 kW Capacity band
Chilled Water Cooling medium
High Density fit
Rack side / closed loop Installation
Rittal
Availability on enquiry
Integrated / micro DC Ceiling

LCP Rack CW/CWG

SK 3314230
20–55 kW Capacity band
Chilled Water Cooling medium
High Density fit
Rack side / closed loop Installation
Rittal
Availability on enquiry
In-row

LCP Inline CW

Inline chilled-water family
20–60 kW Capacity band
Chilled Water Cooling medium
High Density fit
Bayed / inline Installation
Rittal
Availability on enquiry
Integrated / micro DC Ceiling

LCP Rack DX

Rack DX / DX-FC family
10–35 kW Capacity band
DX Cooling medium
Medium–high Density fit
Rack side Installation
COOLING SOLUTION How we develop your cooling solution Explore our simple four-step process
From catalogue to engineered solution

Compare your options. We’ll design the cooling solution.

Choose and compare models here. Request prices on WhatsApp, or contact our team for project and technical details.

Technical details · Contact Us ↗
01
Input the heat load

Use kW or TR and define rack density, room dimensions and deployment type.

02
Filter the architecture

Choose room, row, rack, rear-door, chiller, thermal wall or liquid cooling.

03
Compare up to four

View capacity, cooling medium, deployment, redundancy suitability and application side by side.

04
Shortlist for engineering

Send your selected models on WhatsApp to request pricing, or contact us for technical support.